Enter the time-domain function and its variable
For f(t)=1, check the familiar 1/s transform under its convergence assumptions.
Calculate Laplace transforms of common time-domain expressions.
This calculator attempts transforms of common polynomials, exponentials, trigonometric functions and combinations supported by the symbolic engine.
It is a symbolic helper rather than a guarantee for every transformable distribution or generalized function. Always verify transform conditions when using the result in engineering or academic work.
A Laplace transform moves a time-dependent expression into the complex frequency variable s.

For f(t)=1, check the familiar 1/s transform under its convergence assumptions.
Transform a supported time-domain function for analysis.
Convergence and initial conditions matter in real applications.
For f(t)=1, check the familiar 1/s transform under its convergence assumptions.
The Laplace transform of the constant function 1 is 1/s where the integral converges. For e^(−2t), the transform is 1/(s+2) under the usual one-sided definition.
Use the real tool above to verify the result. The example illustrates the workflow, not a guaranteed outcome.
The Laplace transform of the constant function 1 is 1/s where the integral converges. For e^(−2t), the transform is 1/(s+2) under the usual one-sided definition.
Laplace transforms have convergence conditions. Similar-looking formulas may only be valid for particular values of the complex variable s.
A Laplace transform moves a time-dependent expression into the complex frequency variable s.
A Laplace transform moves a time-dependent expression into the complex frequency variable s.
For f(t)=1, check the familiar 1/s transform under its convergence assumptions.
The Laplace transform of the constant function 1 is 1/s where the integral converges. For e^(−2t), the transform is 1/(s+2) under the usual one-sided definition.
Laplace transforms convert a suitable time-domain function f(t) into an s-domain function F(s) through an integral with an exponential kernel. For a constant function f(t)=1 and the usual one-sided convention, the result is 1/s for Re(s)>0. For f(t)=e^(−2t), the result is 1/(s+2), with its own convergence condition. Enter the function of the original variable and identify the transform variable explicitly; the mathematical output is an expression in a different variable.
Trigonometric inputs show why coefficients matter. The Laplace transform of sin(3t) is 3/(s²+9), while cos(3t) transforms to s/(s²+9). They have the same denominator but different numerators. One can check an answer by taking its inverse transform or consulting a standard transform pair. Do not confuse multiplying by t in the input with shifting s in the output; the relevant transform properties are distinct.
The transform of a derivative introduces initial values: for a differentiable f, L{f'} = sF(s) − f(0) under ordinary one-sided assumptions. This makes Laplace transforms useful for solving initial-value problems because differentiation becomes algebraic in s. For y' + 2y = 0 and y(0)=5, the transformed equation yields (s+2)Y(s)=5; thus Y(s)=5/(s+2), corresponding to 5e^(−2t). Forgetting the initial-value term is a frequent source of wrong solutions.
Not every function has an ordinary Laplace transform for every complex s. The integral may converge only within a region, and impulses or discontinuities can require generalized-function conventions. The symbolic parser also needs unambiguous multiplication and powers. A displayed algebraic expression without convergence conditions is not an unrestricted equality over the entire complex plane. For physical models, time must have a consistent unit, and growth/decay constants must be measured in reciprocal-time units.
When applying a Laplace expression to circuits or control models, identify whether you transformed an input signal, an output response or a system equation. An expression can be correct algebraically yet unsuitable for the quantity you meant to model. For independent verification, choose a common pair, check the sign in terms such as s+a or s−a, and compare inverse transform to the original input. Retain any assumptions about t≥0 and initial conditions in the exported notes.
Transforms are linear: for appropriate functions, L{2f(t)+3g(t)} = 2F(s)+3G(s). Therefore the transform of 2+3e^(−t) is 2/s + 3/(s+1) under standard one-sided assumptions. A result that loses a coefficient is suspicious, particularly when copying expressions with several terms. The region of convergence of a sum also deserves care; each component must be defined for the chosen s values. When checking with a transform table, make sure it uses the same definitions, initial time and scaling conventions as the computation.
A switched-on constant signal is represented by a unit step in elementary one-sided transform exercises. Its transform is 1/s under the usual assumptions for a signal active from t=0 onward. A delayed step requires a shift term and should not be confused with a constant that has been active for all time. If a physical system switches at t=5 seconds, the event time changes the transform; a student copying 1/s without noting the delay would model a different input.
A time-domain input such as f(t) = t should transform to 1/s² under the usual one-sided causal Laplace definition. If the source is f(t) = e^(−3t), the familiar result is 1/(s+3). These checks help distinguish an exponent coefficient from a time shift. Keep the transform variable s separate from time t when reading the result. An expression may be valid only when the real part of s lies in a suitable region; ignoring convergence can give a formally familiar formula outside its mathematical conditions. This utility is for supported symbolic expressions, not a replacement for a measurement instrument collecting an actual electrical waveform.
No. The usual Laplace transform of the constant function has a convergence condition, commonly Re(s) greater than zero.
A symbolic fraction alone omits where the defining improper integral actually converges.
No. A mathematical function must be supplied; measured signals require separate sampling and modelling before a transform is meaningful.
For f(t)=1 under the usual causal convention, the transform is 1/s in its valid convergence region.